Main functions
- Suitable for rated voltageUsed for starting, stopping, and running indication of three-phase asynchronous motors with a rated voltage of AC690V and below. It has protection for motor overload, short circuit, phase loss, and undervoltage.
- It can realize remote control start and stop, current and voltage parameter measurement, and running status and alarm display functions.
- Equipped with an intelligent motor management module, it can communicate with the motor central control device to realize the function of decentralized control and centralized management.
- Starting methods include: direct starting, star-delta starting, soft starting, frequency conversion starting, and autotransformer reduced-voltage starting.
- Reversible and multi-speed starting can be achieved.
- The product meets the basic requirements of GB/T3783-2019 marine low-voltage electrical appliances and the relevant standards of various classification societies.
Main Technical Parameters
- Rated voltage: AC690V/AC480V/AC440V/AC380V
- Rated frequency: 50/60Hz
- Motor power: Below 300KW
- Protection level: IP/23/IP44/IP56